Rummel FlowCon Automatic Flow and Temperature Control System
✓ Automatic flow setting with an electronic proportional valve in every circuit
✓ Control that holds the supply-return temperature difference constant
✓ Automatic flow or automatic temperature control mode
✓ Vortex piezoceramic sensor, 1.0–20 L/min
✓ Control up to 100 °C (technical table max. 120 °C), 10 bar
✓ Manifold with 2–12 stations, up to 100 circuits by cascade
RUMMEL — Germany

Rummel FlowCon Automatic Flow and Temperature Control System

Multi-circuit distribution system that adjusts the flow in every mold circuit automatically with an electric proportional valve and keeps the supply-return temperature difference constant.

Technical Specifications
Max. temperatureControl up to 100 °C; technical table max. 120 °C
Max. operating pressure10 bar
Measuring range1.0–20 L/min
Measuring principleVortex – piezoceramic sensor element
Mode of operationAutomatic flow or temperature control (supply-return temperature difference)
Number of circuitsManifold with 2, 3, 4, 5, 6, 8, 10 and 12 stations; up to 100 circuits by cascade connection
Main line connection1" female thread
Mold circuit connection1/2" female thread
MaterialParts in contact with the medium in brass and stainless steel
SealFKM (Viton)
MediumWater
Circuit controlElectronic proportional valves
// About the Product

Product Description and Technical Details

Rummel FlowCon: the distributor that controls, not just measures

FlowCon is the model in the Rummel multi-circuit distribution family that adjusts the flow itself. In the other models each circuit is set with a hand-operated ball valve, and the system only measures and warns. In FlowCon, by contrast, each circuit has an electronic proportional valve; the control electronics position the valve continuously and automatically to hold the flow or the temperature at the required value.

How does temperature difference control work?

The key function of FlowCon is control of the supply-return temperature difference. The controller compares the supply and return water temperatures of each circuit and adjusts the flow via the proportional valve so that the difference between the two temperatures stays constant. The temperature difference is a direct indicator of the heat that circuit takes from the mold. When the difference is held constant, each circuit draws as much heat from the mold as it needs: more water goes to the circuit in the hot zone, and no unnecessary flow is spent in a circuit with a low heat load.

The result of this approach is the three gains the manufacturer emphasizes: shorter cycle times, energy savings and more stable quality through monitored processes. Because the flow is adjusted automatically when needed, dependence on the operator's valve setting also disappears.

Operating modes

FlowCon can be run in two ways: automatic flow control (the flow set for each circuit is held) or automatic temperature control (the temperature target is reached by adjusting the flow). The flow is measured with a vortex piezoceramic sensor element in the range 1.0–20 L/min; temperature and optional pressure are monitored in every circuit.

A note on the temperature limit

The manufacturer defines the automatic flow and temperature control of FlowCon for applications up to 100 °C; the technical table of the same brochure gives the maximum temperature as 120 °C. We recommend planning the control function for circuits up to 100 °C and clarifying use between 100 and 120 °C together at the quotation stage.

Technical data

FeatureValue
Circuit controlElectronic proportional valves
Mode of operationAutomatic flow or temperature control
Measuring principleVortex – piezoceramic sensor element
Measuring range1.0–20 L/min
Main distribution connection1" female thread
Mold circuit connection1/2" female thread
MaterialParts in contact with the medium in brass and stainless steel
SealFKM (Viton)
MediumWater
Control temperatureUp to 100 °C
Max. temperature (technical table)120 °C
Max. operating pressure10 bar
Modular designManifold with 2, 3, 4, 5, 6, 8, 10 and 12 stations; up to 100 circuits by cascade connection

When FlowCon?

In molds with many circuits where the heat load varies markedly from zone to zone, for example parts that combine thick and thin walls, a manual valve setting either overcools one zone or leaves another one short. FlowCon sets each circuit according to its own heat load. For applications where a manual setting is enough and only monitoring is wanted, FlowBasic is the simpler solution.

Visualization, alarms, and logging of mold parameters and process data are standard on FlowCon as well; interface and screen options are on the control unit and operator panel page.

Technical Specifications

Max. temperatureControl up to 100 °C; technical table max. 120 °C
Max. operating pressure10 bar
Measuring range1.0–20 L/min
Measuring principleVortex – piezoceramic sensor element
Mode of operationAutomatic flow or temperature control (supply-return temperature difference)
Number of circuitsManifold with 2, 3, 4, 5, 6, 8, 10 and 12 stations; up to 100 circuits by cascade connection
Main line connection1" female thread
Mold circuit connection1/2" female thread
MaterialParts in contact with the medium in brass and stainless steel
SealFKM (Viton)
MediumWater
Circuit controlElectronic proportional valves