Request a Quote →
MRC065PSV Inverter Modular Chiller. Cooling 65 kW. IPLV 4.3.4 models
Oksan — Turkey

Industrial Chillers and Cooling Units

MRC065PSV Inverter Modular Chiller. Cooling 65 kW. IPLV 4.3.

Air-cooled modular chiller with inverter scroll compressors; IPLV up to 4.50, stepless capacity. 65–150 kW.

Cooling Capacity65 kW
Heating Capacity70 kW
Compressor1 × inverter scroll
RefrigerantR410A
Water Flow11.2 m³/h
Cooling Capacity65 kW
Heating Capacity70 kW
Compressor1 × inverter scroll
RefrigerantR410A
Water Flow11.2 m³/h
// About the Product

Product Description and Technical Details

The inverter series is a family of air-cooled modular chillers with inverter (variable-frequency) scroll compressors. A fixed-speed compressor either runs at full load or stops; an inverter compressor adjusts its speed to demand. As a result, the leaving water temperature stays more stable and energy consumption drops markedly at part load.

Part-load efficiency: IPLV

Chillers spend most of the year below full load. That is why their efficiency is better shown by the IPLV (integrated part load value) than by the full-load coefficient. In this series the IPLV is 4.30 for the PSV models and 4.50 for the PLV models.

Model selection within the series

ModelCoolingHeatingIPLVMinimum outdoor temperature in heating
MRC065PSV65 kW70 kW4.30−15 °C
MRC130PSV130 kW138 kW4.30−15 °C
MRC075PLV75 kW80 kW4.50−26 °C
MRC150PLV150 kW160 kW4.50−26 °C

As heat pumps, the PLV models can also heat in very cold outdoor conditions (down to −26 °C). If only process cooling is needed, the main difference between PSV and PLV is efficiency and capacity.

Design

  • Inverter scroll compressor, R410A refrigerant, electronic expansion valve
  • Vacuum-brazed plate heat exchanger on the water side
  • Low-noise axial fans; optional quiet mode
  • Wired controller (PJAC-T-A301)

Operating range

Outdoor temperature 5–48 °C in cooling; chilled water 5–20 °C, hot water 30–55 °C.

Nominal cooling test conditions (manufacturer's catalog): water flow 0.172 m³/(h·kW), leaving water 7 °C, ambient 35 °C.

For a comparison of the series, see the industrial chillers category.

Technical Specifications

Cooling Capacity65 kW
Heating Capacity70 kW
Compressor1 × inverter scroll
RefrigerantR410A
Water Flow11.2 m³/h