Industrial Chillers and Cooling Units

Modular chillers with scroll compressors

Industrial Chillers and Cooling Units Products(3)

What is an industrial chiller?

A chiller (water chiller, cooling unit) is a refrigeration machine that cools process water to a set temperature and supplies it to the consumers in a closed loop. In injection molding, chilled water goes to the mold cooling channels, the machine's hydraulic oil heat exchanger, the material feed throat and the calibration sections of blow molding and extrusion lines. Because the heat that has to be removed from the mold directly determines the cycle time, chiller capacity is one of the limits on production speed.

The units in this category are modular chiller series with scroll compressors offered by our group company Oksan. There are three series:

SeriesCondenserCompressorNominal coolingHighlight
Standard series (MRC…PST)Air-cooledHermetic scroll65–270 kWAlso heats as a heat pump
Inverter series (MRC…PSV / PLV)Air-cooledInverter scroll65–150 kWIPLV 4.30–4.50, stepless capacity
Water-cooled series (MRC…W)Water-cooled (tower)Hermetic scroll85–340 kWCompact body, indoor installation

What does a modular design offer?

Each unit runs in stages internally, and several units can be connected to operate as a single system (up to 16 units according to the catalog). A single stepped unit adjusts its capacity in four levels (0–25–50–75–100%), while a modular system adjusts it in steps of roughly 1.5%. At part load only the compressors that are needed run; the controller balances the running hours of the compressors and starts the least-used compressor first.

A modular installation has two practical benefits: units are added as the plant grows, so you do not have to buy the largest capacity on day one, and while one unit is under maintenance the others keep cooling.

Air-cooled or water-cooled?

  • Air-cooled (standard and inverter series): rejects condenser heat to the ambient air and needs no cooling tower. It is installed outdoors; in summer the outdoor temperature affects capacity (cooling operating range 5–48 °C).
  • Water-cooled: transfers condenser heat to the cooling tower circuit. The body is smaller and can be installed indoors; if the plant has a tower circuit, efficiency is higher.

What to check when selecting

1. Actual heat load: the mold cooling load is calculated from the hourly plastic throughput and the enthalpy of the material; the hydraulic oil cooling load depends on the machine's drive type. Our mold cooling and oil cooling calculators give you this load. 2. Water temperature: chiller leaving water is in the 5–20 °C range. If the mold runs above 20 °C, a water mold temperature control unit is placed between the chiller and the mold. 3. Flow rate: at nominal conditions, a water flow of 0.172 m³/h per kW is taken as the basis; the pump and pipe size are selected accordingly. 4. Part load: if production varies during the day, the inverter series or a modular installation lowers energy consumption.

For compact process units that combine heating and cooling in one cabinet, see the Termojel heating-cooling units category. For a quote and a capacity calculation, contact our technical support team.