Control Modules
Input and output modules and control cards of the machine control system.

Modules are the nerve endings of the control system. They read the signal coming from sensors, drive outputs to valves and heaters, and communicate with the main processor. When a module fails, it is usually not the whole machine but a particular axis or heater group that drops out.
These parts are specific to the control family and lead times can be longer than for mechanical parts. If your machine park holds more than one machine from the same control family, a single spare set covers several machines at once — keeping critical modules on the shelf cuts downtime from days to hours.
Part List
The list below gives the part name, manufacturer, manufacturer code and size. Type a manufacturer code or a dimension into the search box to filter it.
| Part | Manufacturer | Manufacturer Code | Size / Type |
|---|---|---|---|
| INSERT,FILTER | ARGO-HYTOS GMBH | S2,1033-21 F | 100MY ES 314-XXX-17855001 |
| INSERT,FILTER | ARGO-HYTOS GMBH | S2,1133-21 F | 100MY ES 445-XXX |
| INSERT,FILTER | ARGO-HYTOS GMBH | S2,1133-21 F | 100MY ES 445-XXX-17854801 |
| MODULE TRANSFER | PHOENIX CONTACT | USA-2MSTBVA12/ZFKDS1,5/SO119 | — |
| MODULE TRANSFER | PHOENIX CONTACT | USA-PVB2/3MSTBVA 16/SC014 | — |
| MODULE TRANSFER | PHOENIX CONTACT | USA-2MSTBVA12/ZFKDS1,5/SO119 | 12POL,4POL,81X53X47/ PITCH 5,08 - 24V 10A - 23 06 11 3 |
| MODULE TRANSFER | PHOENIX CONTACT | USA-PVB2/3MSTBVA 16/SC014 | 2X16-POL,0V+1X16POL,24V/81X53X47 - 24V 10A/ 24A - 29 00 78 7 |
| MODULE TRANSFER | PHOENIX CONTACT | USA-PVB2/3MSTBVA 16/SO118 | 81X53X47/2X16-POL,0V+1X16POL,24V - 24V 10A/ 24A - 23 06 10 0 |
| MODULE,TECHNOLOGY | SIGMATEK | C-TMS020-K / 12-250-011-K | — |
| MODULE | SIGMATEK | C-M5M 031 / 12-250-031 | — |
| MODULE | SIGMATEK | CAI 883 / 12-009-883 | — |
| MODULE,MIXING,DIGITAL | SIGMATEK | CDM 167 / 12-008-167-O | — |
| MODULE | SIGMATEK | C-M5S 021 / 12-720-021 | — |
| MODULE,PROCESSING UNIT | SIGMATEK | 12-104-512-K / CCP512-K EDGE-CPU | — |
| MODULE,SPLITTER | SIGMATEK | VSV046 / 16-023-046 | — |
| MODULE,EXIT,DIGITALLY | SIGMATEK | CTO 167 / 12-007-167-1 | — |
| MODULE,INTERFACE | SIGMATEK | CEZ 201 / 12-051-201-0 | — |
| MODULE | SIGMATEK | C-M5S 021 / 12-720-021 | +5V, MEPURPLEY 2 KBIT - C-DIAS - HW 2,0 |
| MODULE | SIGMATEK | CEZ 161 / 12-051-161 | 10 INPUT / 6 OUTPUT - HW 1,1 |
| MODULE,INTERFACE | SIGMATEK | CEZ 201 / 12-051-201-0 | 10DI+10DO RELAY - C-DIAS /E67 - HW 1,0 |
| MODULE,EXIT,DIGITALLY | SIGMATEK | CTO 167 / 12-007-167-1 | 16 DIGI-OUTPUT, 24V/DC 2A O,LED - C-DIAS/KS-FIXED - HW 1,2 |
| MODULE,EXIT,DIGITALLY | SIGMATEK | CTO 167 / 12-007-167-1 | 16 DIGI-OUTPUT, 24V/DC 2A O,LED - C-DIAS/KS-FIXED HW 1,2 |
| MODULE,INPUT,DIGITALLY | SIGMATEK | CDI 161 / 12-006-161-O | 16 DIGI-INPUT, 24V/DC (5MS) O,LED - C-DIAS - HW 1,3 |
| MODULE,INPUT,DIGITALLY | SIGMATEK | CDI 161 / 12-006-161-O | 16 DIGI-INPUT, 24V/DC (5MS) O,LED - HW 1,3 - C-DIAS |
| MODULE,INPUT,DIGITALLY | SIGMATEK | CDI169 / 12-006-169-O | 16 DIGI-IN COUNTER NPN - C-DIAS HW 1,0 |
| MODULE,INPUT,DIGITALLY | SIGMATEK | CSDI 161 / 12-891-161 | 16 DIGI-SAFETY-INPUT, 24V/DC (5MS) - C-DIAS-SAFETY - HW4,0 X1,2 |
| MODULE | SIGMATEK | CRO 081 / 12-064-081-O | 2 CHANGEOVER CONTACT / 6 NORMALLY OPEN - C-DIAS - HW 1,1 |
| MODULE,INTERFACE | SIGMATEK | CCA121 / 12-025-121 | 2 X CAN - HW N,N |
| MODULE,SPLITTER | SIGMATEK | VSV046 / 16-023-046 | 5 X VARANOUT SWITCHABLE - VARAN - HW1,30 X1,4 |
| MODULE | SIGMATEK | DKL361 05-024-361 | 50X80X98 DEE021 ENERGY METERING, - VARAN - HW 2,0 |
| MODULE,PROCESSING UNIT | SIGMATEK | 12-104-512-K / CCP512-K EDGE-CPU | 512 MB SD-256 MB RAM-800 MHZ - BST 1,3,012E - HW3,0 X1,5 |
| MODULE,PROCESSING UNIT | SIGMATEK | 12-104-612-K / CCP612 EDGE-CPU | 512MB SD-256MB RAM-800 MHZ - BST 1,3,012E - HW3,00 X1,6 |
| MODULE,MIXING,DIGITAL | SIGMATEK | DM 167 / 12-008-167-O | 8 OUTPUT,/INPUT, 24V/DC 2A O,LED - C-DIAS/KS-FIXED |
| MODULE,MIXING,DIGITAL | SIGMATEK | CDM 167 / 12-008-167-O | 8 OUTPUT,/INPUT, 24V/DC 2A O,LED - C-DIAS/KS-FIXED - HW 1,1 |
| MODULE,EXIT,DIGITALLY | SIGMATEK | CSTO 081 / 12-892-081 | 8 DIGI-SAFETY-OUTPUT, 24V/DC 2A - C-DIAS-SAFETY -HW4,0 X1,2 |
| MODULE,INPUT,ANALOG | SIGMATEK | CAI 0811 / 12-009-0811 | 8 X ANALOG INPUT PT100/1000/KTY10 - HW N,N |
| MODULE,INPUT,ANALOG | SIGMATEK | CAI 085 / 12-009-085 | 8 X ANALOG INPUT WITH 12 BIT - C-DIAS - HW 2,10 |
| MODULE | SIGMATEK | CLV 011 / 12-731-011 | 8DI+ 8DO+ 4AI - C-DIAS - HW 1,0 |
| MODULE,INPUT,ANALOG | SIGMATEK | CAI 084 / 12-009-084 | 8X ANALOG INPUT 0 - 20 MA - HW 1,X |
| MODULE | SIGMATEK | CAI 883 / 12-009-883 | 8X THERMOCOUPLE INPUT,+8XDIG,OUTPUT,70MA - C-DIAS/FECUNI HW 3,0 |
| MODULE | SIGMATEK | CAO 081 / 12-010-081 | 8XAA +/-10V,12BIT, 2X 8POL, - C-DIAS |
| MODULE | SIGMATEK | er CAO 081 / 12-010-081 | 8XAA +/-10V,12BIT, 2X 8POL, - C-DIAS |
| MODULE | SIGMATEK | CAM 123 / 12-017-123 | 8XAE 0-10V/14BIT+4X AA+/-10V - HW3,5/X2,3 |
| MODULE | SIGMATEK | DEE 021 / 05-068-021 | W/H/D 98/ 45/ 93 MM - VARAN - HW1,4 SW1,2 |
| MODULE,TECHNOLOGY | SIGMATEK | C-TMS020-K / 12-250-011-K | C-DIAS -HW 8,1-X2,8 |
| MODULE,TRANSSONAR | SIGMATEK | CTS 051 / 12-053-051 | F, 5 POSITION MEASURING SYSTEM - HW2,00 X1,2 |
| MODULE | SIGMATEK | C-M5M 031 / 12-250-031 | MACHINE DATA - F,M5 CONTROL - HW 1,0 |
| MODULE,INTERFACE | SIGMATEK | SIGNALEXTENDER / 01-311-011 | HW 1,1 |
| MODULE,INTERFACE | SIGMATEK | HMI-LINK STANDARD / 01-311-012 | HW2,1 SW1,7 |
| MODULE,TECHNOLOGY | SIGMATEK | CTMS030 / 12-250-013-K | HW2,30 X1,3/X1,0 |
| UNIT,DISPLAY | SIGMATEK | M5V121/12-300-121 | 358X313X 62 MM - DIAS - HW 9,0 A1,3 |
| UNIT,DISPLAY | SIGMATEK | M5V121/12-300-121 | Display |
| UNIT,DISPLAY | SIGMATEK | TAE1921-K / 12-200-1921-K | Display |
| UNIT,DISPLAY | SIGMATEK | TAE1922-K / 12-200-1922-K | Display |
| UNIT,DISPLAY | SIGMATEK | TAE1911-K / 12-200-1911-K | Display |
| UNIT,DISPLAY | SIGMATEK | TAE1911-K / 12-200-1911-K | TFT 19 INCH |
| UNIT,DISPLAY | SIGMATEK | TAE1921-K / 12-200-1921-K | TFT 19 INCH MEMBRANE TOUCH |
| UNIT,DISPLAY | SIGMATEK | TAE1922-K / 12-200-1922-K | TFT 19 INCH GLASS TOUCH - HW4,0 SW1,7 |
Is it time to replace?
- A particular axis or heating zone dropping out completely
- The fault LED on the module lighting up
- Inputs not being read, outputs not responding
- A control fault at start-up, a module not recognized warning
What to send us when you order
- The manufacturer code and hardware revision on the module
- Control family and machine model
- The slot number of the module and its function (digital input, analog output, and so on)
- The symptom of the failure — another part may produce the same symptom
Our inventory is wider than this list and it keeps growing. Send us the part code and we will come back with availability and lead time. Adding the machine model and, if you have one, a photograph of the part will speed things up.