Dehumidification That Prevents Mold Sweating
Blue Air Systems
Blue Air Systems
Blue Air SystemsWhen the temperature of the mold surface falls below the dew point of the ambient air, the moisture in the air condenses on the mold surface. In the field this is called mold sweating. Especially in the summer months, on molds working with cold water, water droplets form both on the mold surface and on the part.
The dehumidification unit treats the mold area as an enclosed space. The warm and humid air in the mold area is drawn into the unit, its moisture is removed and it is returned to the mold area as dry air. The air circulates in a closed loop. The mold water can therefore be kept at a low temperature and no sweating occurs.
Blue Air DMS units remove the moisture without using cooling water, with their own cooling circuit; a pre-cooler is not needed either. Because the enclosure surrounding the mold area is made with a sliding cover or quickly removable panels, the mold change is not slowed down.
| Model | Process air | Use |
|---|---|---|
| DMS | 500 – 5,000 Nm³/h | A single production machine |
| DMS Module | 5,000 – 15,000 Nm³/h | Production lines and central systems |
| DMSterile | A DMS option | Air free of germs and viruses, packaging and medical production |
Dehumidification has to be considered together with the mold temperature control units that determine the temperature of the mold water: the temperature control unit keeps the mold cold, and dehumidification prevents sweating at that temperature.